Description
he APS-RTx PowerLine Flex PL31 FL 10.0k HC provides continuous, conditioned power for critical equipment that cannot tolerate interruptions, voltage fluctuations, frequency instability or poor power quality.
Using online double-conversion technology, connected equipment is continuously powered through the UPS inverter, providing zero transfer time between utility and battery operation.
With a full 10kVA / 10kW output capacity and 1.0 power factor, the UPS can deliver its full rated apparent power as usable active power, making it well suited to modern servers, networking systems and other high-density electronic loads.
The three-phase input and single-phase output configuration allows the UPS to draw power across a three-phase supply while delivering a stable 220/230/240VAC single-phase output to the protected load.
Its rack/tower convertible 3U design provides flexibility for installation in server racks, communications racks, equipment rooms or as a standalone floor-mounted system.
For applications requiring increased capacity or redundancy, multiple units can be operated in parallel. This makes the PL31 FL 10.0k HC suitable for systems where future expansion or N+X redundancy is required.
As a long-run UPS, the unit does not contain internal batteries. External battery banks can therefore be selected according to the required backup duration, allowing significantly longer runtimes than standard internal-battery UPS systems.
USB, RS232 and the intelligent communication slot provide options for UPS monitoring, remote management and integration with network or building-management systems.
Key Features
- 10kVA / 10kW rated capacity
- 1.0 output power factor
- Online double-conversion technology
- 3-phase input / 1-phase output
- Rack/Tower convertible
- Compact 3U rack format
- Zero transfer time from utility to battery
- Pure sine-wave output
- Wide 208–478VAC three-phase input range
- 40–70Hz input frequency range
- Input power factor ≥0.99
- Low input harmonic distortion
- 220 / 230 / 240VAC selectable output
- Output voltage regulation ±1%
- Parallel operation supported
- Supports N+X parallel redundancy
- Up to 4 UPS units in parallel
- Dual-input source capability
- Generator compatible
- ECO operating mode
- Frequency-converter mode
- Cold-start capability
- Intelligent fan-speed control
- LCD status display
- USB communication
- RS232 communication
- Intelligent communication slot
- EPO functionality
- External battery-bank support
- High-capacity battery charger
- Battery overcharge and over-discharge protection
- Overload, short-circuit and over-temperature protection
Typical Applications
Suitable for:
- Server rooms
- Data centres
- Network infrastructure
- Telecommunications equipment
- Banking and financial systems
- Security and surveillance systems
- CCTV control rooms
- Access-control infrastructure
- Business-critical IT systems
- Laboratory equipment
- Industrial control systems
- Automation equipment
- Medical support equipment
- Communications racks
- Branch IT infrastructure
- Mission-critical office systems
Technical Specifications
| Specification | PL31 FL 10.0k HC |
|---|---|
| UPS Type | Online Double Conversion |
| Configuration | Rack/Tower Convertible |
| Rack Height | 3U |
| Phase | 3 Phase Input / 1 Phase Output |
| Rated Capacity | 10,000VA / 10,000W |
| Output Power Factor | 1.0 |
| Nominal Input Voltage | 380 / 400 / 415VAC, 3Ph + N + PE |
| Three-Phase Input Range | 208–478VAC |
| Operating Frequency Range | 40–70Hz |
| Input Power Factor | ≥0.99 |
| Input THDi | ≤3% with linear load |
| Nominal Output Voltage | 220 / 230 / 240VAC |
| Output Voltage Regulation | ±1% |
| Output Frequency | 50 / 60Hz |
| Output Waveform | Pure Sine Wave |
| Crest Factor | 3:1 |
| Output THDv | ≤2% linear load / ≤5% non-linear load |
| Transfer Time – AC to Battery | 0ms |
| Inverter to Bypass | 0ms |
| Parallel Capability | Yes |
| Maximum Parallel Units | 4 |
| Parallel Configuration | Capacity Expansion / N+X Redundancy |
| Battery Configuration | External Battery Bank |
| Internal Batteries | None |
| Battery Type | External VRLA or compatible battery system |
| Supported Battery Quantity | 16 / 18 / 20 batteries per string; extended configurations supported |
| Recommended for Full 10kW Output | 20 × 12V batteries per string |
| Maximum Charging Current | Approx. 14A |
| Communications | USB, RS232, Intelligent Slot |
| Generator Compatible | Yes |
| ECO Mode | Yes |
| Cold Start | Yes |
| Dual Input | Supported |
Long-Run Battery Configuration
The PL31 FL 10.0k HC does not include internal batteries.
This allows the UPS battery system to be engineered according to the required backup duration.
External battery banks can therefore be configured for applications requiring:
- Short-duration shutdown protection
- 30-minute backup
- 1-hour backup
- Multi-hour backup
- Extended generator-start support
- Critical-load continuity during prolonged outages
For operation at the full 10kVA / 10kW PF1.0 rating, a 20 × 12V battery configuration per string is recommended.
Additional parallel battery strings may be added where greater runtime is required, subject to correct battery-bank design, protection and charging requirements.