How to Size a Solar, Inverter & Battery System

admin, August 27, 2026August 27, 2026

How to Size a UPS for your Project

What size inverter, battery and solar system do I need?

This is one of the most common questions from homeowners and businesses considering solar power in Ghana.

The mistake is trying to answer it with one number.

A properly sized solar and backup system needs to answer three different questions:

How much power do you need?

How much energy do you use?

How long do you need backup?

Decide Why You Want Solar

Before calculating panels or batteries, decide what you actually want the system to achieve.

Your priority may be:

  • Backup during power outages
  • Lower electricity bills
  • Reduced generator fuel consumption
  • Solar power during the day
  • Backup for critical equipment
  • Whole-building backup
  • Greater energy independence

A battery backup system, solar-only system and solar + battery system can be very different even when they serve the same building.

Check Whether Your Building Is Single or Three Phase

Your building’s electrical supply matters when selecting the inverter.

A small home may be single phase, while larger homes and many commercial buildings use three-phase power.

For three-phase installations, the system should consider both total demand and how the loads are distributed across the phases.

Large three-phase equipment must also be identified separately.

Calculate Your Maximum Power Demand

The inverter must be large enough to operate the equipment that may run simultaneously.

This is measured in kW or kVA.

Air conditioners, pumps, refrigerators and motors may also require additional power briefly when they start.

Modern storage inverters can often provide substantially more than their continuous rating for a short period, so a momentary motor-starting surge does not always mean the inverter needs to be permanently oversized.

The actual inverter overload specification still needs to be verified before final selection.

Calculate Your Daily Energy Use

Solar and battery sizing also require kWh, not just kW.

For example:

A 1kW appliance running for 5 hours consumes:

1kW × 5 hours = 5kWh

That means two homes with the same maximum load can require completely different solar and battery capacities if one uses its appliances for much longer each day.

This is why a good solar sizing calculator asks both equipment wattage and expected operating hours.

Size the Battery for the Backup Time You Need

Battery size depends on:

average protected load × required backup time.

If your backed-up equipment averages 3kW and you want approximately four hours of backup, the starting energy requirement is:

3kW × 4 hours = 12kWh

The actual battery bank will need to be larger because battery capacity, usable depth of discharge and inverter losses must also be considered.

Lithium and lead-acid batteries should not be treated identically.

Size Solar Panels Using Local Solar Production

Solar panel sizing should not simply assume that every 1kW of panels generates 1kW all day.

Actual solar production changes with:

  • Location
  • Month
  • Weather
  • Panel orientation
  • Temperature
  • Shading
  • System losses

For this reason, our Solar Sizing Calculator uses location-based monthly solar-production data.

Rather than sizing only from an annual average, the calculator can look at the lower-producing months and estimate the PV capacity needed to meet the selected energy requirement.

This produces a more useful preliminary solar size for homes and businesses.

Solar, Battery and Inverter Sizes Are Different

Remember:

Inverter kW/kVA determines how much equipment can operate at once.

Battery kWh determines how long your equipment can operate without another power source.

Solar kWp determines how much solar energy can be produced.

A properly designed system balances all three.

Use Our Solar & Inverter Sizing Calculator

Use our free Solar, Inverter & Battery Sizing Calculator for Ghana to enter your appliances, operating hours, building phase and required backup time.

The tool estimates your inverter size, battery capacity and solar PV requirement to give you a practical starting point before purchasing or installing a system.


Generator Sizing Calculator

Email Support

support@axtrongroup.com

Phone Support

+233(0)50 364 7036

Final thought — design around how you actually use power

The best solar and inverter system is not necessarily the one with the most panels or the largest battery. It is the one that matches how much power you use, when you use it and what you want the system to achieve. Start with the real load, decide how much backup you need, then size the inverter, battery and solar array as one complete system. That balance gives you better reliability, better value and a system that works the way you expect.

Energy Management Guides & Resources Industry & Technology Power & Backup Systems Renewable Energy Solar Solutions backup powerBattery StorageEnergy StorageGhana SolarHybrid InverterInverter SizingLithium BatteryRenewable EnergySolar CalculatorSolar EnergySolar PVSolar Sizing

Post navigation

Previous post

Related Posts

Renewable Energy

Driving Long-Term Savings: How Renewable Energy Reduces Business Costs

October 1, 2024October 2, 2025

Every operation that relies on power knows where the money leaks. Energy bills fluctuate, generator fuel and servicing add repeated line items, and outages cost both revenue and reputation. Installing commercial solar and modern storage is not just a sustainability step — it is a financial one. With the right design and financing, solar cuts recurring energy spend, reduces maintenance exposure, and improves uptime, turning energy from a variable cost into a predictable asset.

Read More
Renewable Energy

​Empowering Business Bottom Lines: Why Grid-Tie Solar is the Ultimate Choice

July 11, 2025October 2, 2025

Every business that pays an electricity bill should consider this: connecting well-designed solar to the grid removes a large, volatile monthly expense and replaces it with predictable, low-cost generation. Grid-tie solar systems let you use the sun when you need it and send excess power back to the grid for credit, so you shrink utility bills without taking on the full complexity or cost of an off-grid system. For most commercial sites, grid-tie is the fastest way to convert energy from a recurring liability into a controllable asset.

Read More
Energy Management

Generator, UPS, or Inverter? Picking the Right Backup Power for Your Site

June 4, 2025October 5, 2025

A facilities manager’s guide to choosing generators, UPS systems and inverter + battery solutions. Compare load, runtime, site limits and cost — and get a practical rollout path.
Focus keywords: backup power, generator vs UPS, inverter backup, facilities manager guide, UPS for banks, generator for industry, inverter battery systems

Read More

Recent Posts

  • How to Size a Solar, Inverter & Battery System
  • How to Size a UPS for your Project: kVA, kW & Battery Runtime
  • How to Size a Generator for Your Project: kVA, kW & Starting Loads
  • Preventive vs Predictive Maintenance: Which Strategy Fits Your Facility?
  • ​Empowering Business Bottom Lines: Why Grid-Tie Solar is the Ultimate Choice

Recent Comments

No comments to show.

Archives

  • August 2026
  • October 2025
  • July 2025
  • June 2025
  • January 2025
  • October 2024

Categories

  • Energy Management
  • Guides & Resources
  • IIoT & Monitoring
  • Industry & Technology
  • Maintenance Strategies
  • Power & Backup Systems
  • Renewable Energy
  • Smart Home Solutions
  • Solar Solutions
  • Energy Management
  • Guides & Resources
  • IIoT & Monitoring
  • Industry & Technology
  • Maintenance Strategies
  • Power & Backup Systems
  • Renewable Energy
  • Smart Home Solutions
  • Solar Solutions
  • visit: axtrongroup.com
©2026 | Axtron Analytica