{"id":303,"date":"2026-08-24T13:47:50","date_gmt":"2026-08-24T13:47:50","guid":{"rendered":"https:\/\/axtron.group\/store\/?post_type=product&#038;p=303"},"modified":"2026-08-24T13:55:46","modified_gmt":"2026-08-24T13:55:46","slug":"aps-rtx-powerline-flex-pl31-20k-p2-b1-kit-2-x-10kva-10kw-power-modules-1-x-2-16kwh-battery-box-20kva-20kw-parallel-online-ups-system","status":"publish","type":"product","link":"https:\/\/axtron.group\/store\/product\/aps-rtx-powerline-flex-pl31-20k-p2-b1-kit-2-x-10kva-10kw-power-modules-1-x-2-16kwh-battery-box-20kva-20kw-parallel-online-ups-system\/","title":{"rendered":"APS-RTx PowerLine Flex PL31-20K-P2-B1-KIT \u2013 2 \u00d7 10kVA\/10kW Power Modules + 1 \u00d7 2.16kWh Battery Box, 20kVA\/20kW Parallel Online UPS System"},"content":{"rendered":"<p class=\"isSelectedEnd\">The <strong>APS-RTx PowerLine Flex PL31-20K-P2-B1-KIT<\/strong> is a scalable <strong>20kVA \/ 20kW online UPS system<\/strong> comprising <strong>2 parallel PL31 FL 10.0k HC power modules<\/strong> and <strong>1 PL31-BR20120FL external battery box<\/strong>.<\/p>\n<p class=\"isSelectedEnd\">The two <strong>10kVA \/ 10kW power modules operate in parallel<\/strong>, providing a combined system capacity of <strong>20kVA \/ 20kW<\/strong> while maintaining the flexibility to expand the installation further as power requirements grow.<\/p>\n<p class=\"isSelectedEnd\">Using <strong>online double-conversion technology<\/strong>, connected equipment is continuously supplied through the UPS inverter, providing stable, conditioned power and <strong>zero transfer time during utility failure<\/strong>.<\/p>\n<p class=\"isSelectedEnd\">Each power module delivers a <strong>1.0 output power factor<\/strong>, allowing the complete system to provide up to <strong>20kW of usable active power<\/strong>.<\/p>\n<p class=\"isSelectedEnd\">The system uses a <strong>3-phase input \/ single-phase output architecture<\/strong>, making it suitable for facilities with three-phase utility supplies and critical single-phase loads.<\/p>\n<p class=\"isSelectedEnd\">The included <strong>PL31-BR20120FL battery box<\/strong> contains <strong>20 \u00d7 12V 9Ah maintenance-free VRLA batteries<\/strong>, providing approximately <strong>2.16kWh of nominal stored battery energy<\/strong>.<\/p>\n<p class=\"isSelectedEnd\">The modular architecture allows the system to be expanded to <strong>up to four PL31 FL 10.0k HC power modules in parallel<\/strong>, providing a maximum scalable capacity of <strong>40kVA \/ 40kW<\/strong>.<\/p>\n<p class=\"isSelectedEnd\">Additional compatible battery boxes can also be added where longer backup duration is required.<\/p>\n<h2>Key Features<\/h2>\n<ul data-spread=\"false\">\n<li><strong>20kVA \/ 20kW<\/strong> total UPS capacity<\/li>\n<li><strong>2 power modules included<\/strong><\/li>\n<li><strong>2 \u00d7 10kVA \/ 10kW power modules<\/strong><\/li>\n<li><strong>1 battery box included<\/strong><\/li>\n<li><strong>1.0 output power factor<\/strong><\/li>\n<li>Online double-conversion technology<\/li>\n<li><strong>3-phase input \/ 1-phase output<\/strong><\/li>\n<li>Parallel UPS architecture<\/li>\n<li><strong>Zero transfer time<\/strong> from utility to battery<\/li>\n<li>Pure sine-wave output<\/li>\n<li>Rack\/Tower convertible power modules<\/li>\n<li>208\u2013478VAC three-phase input range<\/li>\n<li>220 \/ 230 \/ 240VAC output<\/li>\n<li>Input power factor \u22650.99<\/li>\n<li>Supports up to <strong>4 power modules in parallel<\/strong><\/li>\n<li>Expandable to <strong>40kVA \/ 40kW<\/strong><\/li>\n<li>Generator compatible<\/li>\n<li>ECO operating mode<\/li>\n<li>LCD status display<\/li>\n<li>USB communication<\/li>\n<li>RS232 communication<\/li>\n<li>Intelligent communication slot<\/li>\n<li><strong>1 \u00d7 2.16kWh battery box included<\/strong><\/li>\n<li><strong>20 \u00d7 12V 9Ah batteries included<\/strong><\/li>\n<li><strong>\u00b1120VDC battery system<\/strong><\/li>\n<li>Additional battery capacity can be added<\/li>\n<li>Overload, short-circuit and battery protection<\/li>\n<\/ul>\n<h2>Typical Applications<\/h2>\n<p class=\"isSelectedEnd\">Suitable for:<\/p>\n<ul data-spread=\"false\">\n<li>Server rooms<\/li>\n<li>Data centres<\/li>\n<li>Banking and financial systems<\/li>\n<li>Network infrastructure<\/li>\n<li>Telecommunications equipment<\/li>\n<li>CCTV and security systems<\/li>\n<li>Access-control infrastructure<\/li>\n<li>Communications racks<\/li>\n<li>Business-critical IT systems<\/li>\n<li>Industrial control systems<\/li>\n<li>Automation systems<\/li>\n<li>Laboratory equipment<\/li>\n<li>Critical office infrastructure<\/li>\n<\/ul>\n<h2>System Technical Specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Specification<\/th>\n<th>PL31-20K-P2-B1-KIT<\/th>\n<\/tr>\n<tr>\n<td>System Type<\/td>\n<td>Parallel Online UPS System<\/td>\n<\/tr>\n<tr>\n<td>UPS Technology<\/td>\n<td>Online Double Conversion<\/td>\n<\/tr>\n<tr>\n<td>Rated Capacity<\/td>\n<td><strong>20,000VA \/ 20,000W<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Output Power Factor<\/td>\n<td><strong>1.0<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Power Modules Included<\/td>\n<td><strong>2<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Power Modules<\/td>\n<td><strong>2 \u00d7 PL31 FL 10.0k HC<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Capacity per Module<\/td>\n<td><strong>10kVA \/ 10kW<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Battery Boxes Included<\/td>\n<td><strong>1<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Input Phase<\/td>\n<td><strong>3 Phase + Neutral + Earth<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Output Phase<\/td>\n<td><strong>Single Phase<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Nominal Input Voltage<\/td>\n<td>380 \/ 400 \/ 415VAC<\/td>\n<\/tr>\n<tr>\n<td>Input Operating Range<\/td>\n<td>208\u2013478VAC<\/td>\n<\/tr>\n<tr>\n<td>Output Voltage<\/td>\n<td>220 \/ 230 \/ 240VAC<\/td>\n<\/tr>\n<tr>\n<td>Output Frequency<\/td>\n<td>50 \/ 60Hz<\/td>\n<\/tr>\n<tr>\n<td>Output Waveform<\/td>\n<td>Pure Sine Wave<\/td>\n<\/tr>\n<tr>\n<td>Transfer Time<\/td>\n<td><strong>0ms<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Parallel Capability<\/td>\n<td><strong>Yes<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Maximum Power Modules<\/td>\n<td><strong>4<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Maximum Expandable Capacity<\/td>\n<td><strong>40kVA \/ 40kW<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Generator Compatible<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Communications<\/td>\n<td>USB, RS232, Intelligent Slot<\/td>\n<\/tr>\n<tr>\n<td>Power Module Installation<\/td>\n<td>Rack \/ Tower<\/td>\n<\/tr>\n<tr>\n<td>Power Module Rack Height<\/td>\n<td><strong>3U each<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Battery Box Rack Height<\/td>\n<td><strong>3U<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Combined Rack Space<\/td>\n<td><strong>9U<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Included Battery System<\/h2>\n<table>\n<tbody>\n<tr>\n<td>Specification<\/td>\n<td>Battery System<\/td>\n<\/tr>\n<tr>\n<td>Battery Box Model<\/td>\n<td><strong>PL31-BR20120FL<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Battery Boxes Included<\/td>\n<td><strong>1<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Batteries per Box<\/td>\n<td><strong>20 \u00d7 12V 9Ah<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Total Battery Quantity<\/td>\n<td><strong>20 \u00d7 12V 9Ah<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Battery Technology<\/td>\n<td>Maintenance-Free VRLA<\/td>\n<\/tr>\n<tr>\n<td>Battery System Voltage<\/td>\n<td><strong>\u00b1120VDC<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Total Series Voltage<\/td>\n<td><strong>240VDC<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Nominal Energy per Box<\/td>\n<td><strong>2.16kWh<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Total Nominal Battery Energy<\/td>\n<td><strong>2.16kWh<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Enclosure<\/td>\n<td>Rack-Mount Battery Box<\/td>\n<\/tr>\n<tr>\n<td>Rack Height<\/td>\n<td><strong>3U<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Battery Capacity<\/h2>\n<p class=\"isSelectedEnd\">The included battery box provides:<\/p>\n<p class=\"isSelectedEnd\"><strong>20 \u00d7 12V \u00d7 9Ah = 2.16kWh nominal battery capacity<\/strong><\/p>\n<p class=\"isSelectedEnd\">Actual backup time depends on:<\/p>\n<ul data-spread=\"false\">\n<li>Connected system load<\/li>\n<li>Battery age and condition<\/li>\n<li>Ambient temperature<\/li>\n<li>Battery discharge rate<\/li>\n<li>UPS operating efficiency<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">For a <strong>20kW system<\/strong>, this configuration prioritizes power capacity over extended runtime. Additional <strong>PL31-BR20120FL battery boxes<\/strong> can be added where longer backup duration is required.<\/p>\n<h2>What&#8217;s Included<\/h2>\n<h3>UPS Power Modules<\/h3>\n<p class=\"isSelectedEnd\"><strong>2 \u00d7 PL31 FL 10.0k HC<\/strong><\/p>\n<p class=\"isSelectedEnd\">Each module provides:<\/p>\n<ul data-spread=\"false\">\n<li>10kVA \/ 10kW<\/li>\n<li>PF1.0<\/li>\n<li>3-phase input<\/li>\n<li>Single-phase output<\/li>\n<li>Rack\/Tower configuration<\/li>\n<li>Parallel capability<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\"><strong>Combined UPS capacity: 20kVA \/ 20kW<\/strong><\/p>\n<h3>Battery Box<\/h3>\n<p class=\"isSelectedEnd\"><strong>1 \u00d7 PL31-BR20120FL<\/strong><\/p>\n<ul data-spread=\"false\">\n<li>20 \u00d7 12V 9Ah batteries<\/li>\n<li>\u00b1120VDC<\/li>\n<li>2.16kWh nominal energy<\/li>\n<li>3U rack enclosure<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p class=\"isSelectedEnd\"><span data-me-change=\"delta\">The <strong>APS-RTx PL31-20K-P2-B1-KIT<\/strong> is a complete 2<strong>0kVA \/ 20kW parallel online UPS<\/strong> system providing 2.16kWh nominal battery capacity for backup of critical equipment and infrastructure.<\/span><\/p>\n<ul data-spread=\"false\">\n<li><span data-me-change=\"delta\"><strong>2 \u00d7 PL31 FL 10.0k HC<\/strong> \u2013 10kVA\/10kW UPS Power Modules<\/span><\/li>\n<li><span data-me-change=\"delta\"><strong>1 \u00d7 PL31-BR20120FL<\/strong> \u2013 2.16kWh Battery Box with 20 \u00d7 12V 9Ah batteries<\/span><\/li>\n<\/ul>\n","protected":false},"featured_media":304,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[30,31],"product_tag":[136,135,124,101,102,69,70,39,97,79,45,137,49,42,75,73,139,40,43,138,48,98,59],"class_list":["post-303","product","type-product","status-publish","has-post-thumbnail","product_cat-ups-backup-power","product_cat-ups-systems","product_tag-1-battery-box-ups","product_tag-2-power-module-ups","product_tag-2-16kwh-battery","product_tag-20kva-ups","product_tag-20kw-ups","product_tag-3-phase-ups","product_tag-31-ups","product_tag-aps-rtx","product_tag-complete-ups-system","product_tag-data-centre-ups","product_tag-double-conversion-ups","product_tag-modular-ups","product_tag-network-ups","product_tag-online-ups","product_tag-parallel-ups","product_tag-pf1-0-ups","product_tag-pl31-20k-p2-b1-kit","product_tag-powerline-flex","product_tag-rack-mount-ups","product_tag-scalable-ups","product_tag-server-ups","product_tag-ups-battery-system","product_tag-ups-ghana","first","instock","taxable","shipping-taxable","purchasable","product-type-woosb"],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/axtron.group\/store\/wp-json\/wp\/v2\/product\/303","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/axtron.group\/store\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/axtron.group\/store\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/axtron.group\/store\/wp-json\/wp\/v2\/comments?post=303"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/axtron.group\/store\/wp-json\/wp\/v2\/media\/304"}],"wp:attachment":[{"href":"https:\/\/axtron.group\/store\/wp-json\/wp\/v2\/media?parent=303"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/axtron.group\/store\/wp-json\/wp\/v2\/product_brand?post=303"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/axtron.group\/store\/wp-json\/wp\/v2\/product_cat?post=303"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/axtron.group\/store\/wp-json\/wp\/v2\/product_tag?post=303"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}