{"id":236,"date":"2026-08-21T00:28:32","date_gmt":"2026-08-21T00:28:32","guid":{"rendered":"https:\/\/axtron.group\/store\/?post_type=product&#038;p=236"},"modified":"2026-08-24T19:23:46","modified_gmt":"2026-08-24T19:23:46","slug":"aps-rtx-powerline-flex-pl31-fl-10-0k-hc-10kva-10kw-31-online-rack-tower-ups","status":"publish","type":"product","link":"https:\/\/axtron.group\/store\/product\/aps-rtx-powerline-flex-pl31-fl-10-0k-hc-10kva-10kw-31-online-rack-tower-ups\/","title":{"rendered":"APS-RTx PowerLine Flex PL31 FL 10.0k HC \u2013 10kVA\/10kW 3:1 Online Rack\/Tower UPS"},"content":{"rendered":"<p class=\"isSelectedEnd\">he <strong>APS-RTx PowerLine Flex PL31 FL 10.0k HC<\/strong> provides continuous, conditioned power for critical equipment that cannot tolerate interruptions, voltage fluctuations, frequency instability or poor power quality.<\/p>\n<p class=\"isSelectedEnd\">Using <strong>online double-conversion technology<\/strong>, connected equipment is continuously powered through the UPS inverter, providing <strong>zero transfer time between utility and battery operation<\/strong>.<\/p>\n<p class=\"isSelectedEnd\">With a full <strong>10kVA \/ 10kW output capacity and 1.0 power factor<\/strong>, the UPS can deliver its full rated apparent power as usable active power, making it well suited to modern servers, networking systems and other high-density electronic loads.<\/p>\n<p class=\"isSelectedEnd\">The <strong>three-phase input and single-phase output<\/strong> configuration allows the UPS to draw power across a three-phase supply while delivering a stable 220\/230\/240VAC single-phase output to the protected load.<\/p>\n<p class=\"isSelectedEnd\">Its <strong>rack\/tower convertible 3U design<\/strong> provides flexibility for installation in server racks, communications racks, equipment rooms or as a standalone floor-mounted system.<\/p>\n<p class=\"isSelectedEnd\">For applications requiring increased capacity or redundancy, multiple units can be operated in parallel. This makes the PL31 FL 10.0k HC suitable for systems where future expansion or <strong>N+X redundancy<\/strong> is required.<\/p>\n<p class=\"isSelectedEnd\">As a <strong>long-run UPS<\/strong>, the unit does not contain internal batteries. External battery banks can therefore be selected according to the required backup duration, allowing significantly longer runtimes than standard internal-battery UPS systems.<\/p>\n<p class=\"isSelectedEnd\">USB, RS232 and the intelligent communication slot provide options for UPS monitoring, remote management and integration with network or building-management systems.<\/p>\n<h3>Key Features<\/h3>\n<ul data-spread=\"false\">\n<li><strong>10kVA \/ 10kW<\/strong> rated capacity<\/li>\n<li><strong>1.0 output power factor<\/strong><\/li>\n<li><strong>Online double-conversion<\/strong> technology<\/li>\n<li><strong>3-phase input \/ 1-phase output<\/strong><\/li>\n<li><strong>Rack\/Tower convertible<\/strong><\/li>\n<li>Compact <strong>3U rack format<\/strong><\/li>\n<li><strong>Zero transfer time<\/strong> from utility to battery<\/li>\n<li>Pure sine-wave output<\/li>\n<li>Wide <strong>208\u2013478VAC three-phase input range<\/strong><\/li>\n<li>40\u201370Hz input frequency range<\/li>\n<li>Input power factor \u22650.99<\/li>\n<li>Low input harmonic distortion<\/li>\n<li>220 \/ 230 \/ 240VAC selectable output<\/li>\n<li>Output voltage regulation \u00b11%<\/li>\n<li><strong>Parallel operation supported<\/strong><\/li>\n<li>Supports <strong>N+X parallel redundancy<\/strong><\/li>\n<li>Up to <strong>4 UPS units in parallel<\/strong><\/li>\n<li>Dual-input source capability<\/li>\n<li>Generator compatible<\/li>\n<li>ECO operating mode<\/li>\n<li>Frequency-converter mode<\/li>\n<li>Cold-start capability<\/li>\n<li>Intelligent fan-speed control<\/li>\n<li>LCD status display<\/li>\n<li>USB communication<\/li>\n<li>RS232 communication<\/li>\n<li>Intelligent communication slot<\/li>\n<li>EPO functionality<\/li>\n<li>External battery-bank support<\/li>\n<li>High-capacity battery charger<\/li>\n<li>Battery overcharge and over-discharge protection<\/li>\n<li>Overload, short-circuit and over-temperature protection<\/li>\n<\/ul>\n<h3>Typical Applications<\/h3>\n<p class=\"isSelectedEnd\">Suitable for:<\/p>\n<ul data-spread=\"false\">\n<li>Server rooms<\/li>\n<li>Data centres<\/li>\n<li>Network infrastructure<\/li>\n<li>Telecommunications equipment<\/li>\n<li>Banking and financial systems<\/li>\n<li>Security and surveillance systems<\/li>\n<li>CCTV control rooms<\/li>\n<li>Access-control infrastructure<\/li>\n<li>Business-critical IT systems<\/li>\n<li>Laboratory equipment<\/li>\n<li>Industrial control systems<\/li>\n<li>Automation equipment<\/li>\n<li>Medical support equipment<\/li>\n<li>Communications racks<\/li>\n<li>Branch IT infrastructure<\/li>\n<li>Mission-critical office systems<\/li>\n<\/ul>\n<h3>Technical Specifications<\/h3>\n<table>\n<tbody>\n<tr>\n<th>Specification<\/th>\n<th>PL31 FL 10.0k HC<\/th>\n<\/tr>\n<tr>\n<td>UPS Type<\/td>\n<td>Online Double Conversion<\/td>\n<\/tr>\n<tr>\n<td>Configuration<\/td>\n<td>Rack\/Tower Convertible<\/td>\n<\/tr>\n<tr>\n<td>Rack Height<\/td>\n<td><strong>3U<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Phase<\/td>\n<td><strong>3 Phase Input \/ 1 Phase Output<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Rated Capacity<\/td>\n<td><strong>10,000VA \/ 10,000W<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Output Power Factor<\/td>\n<td><strong>1.0<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Nominal Input Voltage<\/td>\n<td>380 \/ 400 \/ 415VAC, 3Ph + N + PE<\/td>\n<\/tr>\n<tr>\n<td>Three-Phase Input Range<\/td>\n<td><strong>208\u2013478VAC<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Operating Frequency Range<\/td>\n<td><strong>40\u201370Hz<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Input Power Factor<\/td>\n<td>\u22650.99<\/td>\n<\/tr>\n<tr>\n<td>Input THDi<\/td>\n<td>\u22643% with linear load<\/td>\n<\/tr>\n<tr>\n<td>Nominal Output Voltage<\/td>\n<td>220 \/ 230 \/ 240VAC<\/td>\n<\/tr>\n<tr>\n<td>Output Voltage Regulation<\/td>\n<td>\u00b11%<\/td>\n<\/tr>\n<tr>\n<td>Output Frequency<\/td>\n<td>50 \/ 60Hz<\/td>\n<\/tr>\n<tr>\n<td>Output Waveform<\/td>\n<td>Pure Sine Wave<\/td>\n<\/tr>\n<tr>\n<td>Crest Factor<\/td>\n<td>3:1<\/td>\n<\/tr>\n<tr>\n<td>Output THDv<\/td>\n<td>\u22642% linear load \/ \u22645% non-linear load<\/td>\n<\/tr>\n<tr>\n<td>Transfer Time \u2013 AC to Battery<\/td>\n<td><strong>0ms<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Inverter to Bypass<\/td>\n<td><strong>0ms<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Parallel Capability<\/td>\n<td><strong>Yes<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Maximum Parallel Units<\/td>\n<td><strong>4<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Parallel Configuration<\/td>\n<td>Capacity Expansion \/ N+X Redundancy<\/td>\n<\/tr>\n<tr>\n<td>Battery Configuration<\/td>\n<td>External Battery Bank<\/td>\n<\/tr>\n<tr>\n<td>Internal Batteries<\/td>\n<td><strong>None<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Battery Type<\/td>\n<td>External VRLA or compatible battery system<\/td>\n<\/tr>\n<tr>\n<td>Supported Battery Quantity<\/td>\n<td>16 \/ 18 \/ 20 batteries per string; extended configurations supported<\/td>\n<\/tr>\n<tr>\n<td>Recommended for Full 10kW Output<\/td>\n<td><strong>20 \u00d7 12V batteries per string<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Maximum Charging Current<\/td>\n<td>Approx. <strong>14A<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Communications<\/td>\n<td>USB, RS232, Intelligent Slot<\/td>\n<\/tr>\n<tr>\n<td>Generator Compatible<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>ECO Mode<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Cold Start<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Dual Input<\/td>\n<td>Supported<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Long-Run Battery Configuration<\/h3>\n<p class=\"isSelectedEnd\">The <strong>PL31 FL 10.0k HC does not include internal batteries<\/strong>.<\/p>\n<p class=\"isSelectedEnd\">This allows the UPS battery system to be engineered according to the required backup duration.<\/p>\n<p class=\"isSelectedEnd\">External battery banks can therefore be configured for applications requiring:<\/p>\n<ul data-spread=\"false\">\n<li>Short-duration shutdown protection<\/li>\n<li>30-minute backup<\/li>\n<li>1-hour backup<\/li>\n<li>Multi-hour backup<\/li>\n<li>Extended generator-start support<\/li>\n<li>Critical-load continuity during prolonged outages<\/li>\n<\/ul>\n<p class=\"isSelectedEnd\">For operation at the full <strong>10kVA \/ 10kW PF1.0 rating<\/strong>, a <strong>20 \u00d7 12V battery configuration per string<\/strong> is recommended.<\/p>\n<p class=\"isSelectedEnd\">Additional parallel battery strings may be added where greater runtime is required, subject to correct battery-bank design, protection and charging requirements.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The <strong data-start=\"1074\" data-end=\"1102\">APS-RTx PL31 FL 10.0k HC<\/strong> is a <strong data-start=\"1108\" data-end=\"1153\">10kVA \/ 10kW online double-conversion UPS<\/strong> with 3-phase input, single-phase output, PF1.0 performance and parallel capability. Its rack\/tower design is ideal for data centres, server rooms and critical infrastructure requiring scalable, high-quality power protection. <strong data-start=\"1379\" data-end=\"1434\">External battery box required for backup operation.<\/strong><\/p>\n","protected":false},"featured_media":244,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[30,31],"product_tag":[67,68,69,70,74,39,79,45,78,77,49,42,75,73,80,63,40,43,58,76,48,72,71,44,59],"class_list":["post-236","product","type-product","status-publish","has-post-thumbnail","product_cat-ups-backup-power","product_cat-ups-systems","product_tag-10kva-ups","product_tag-10kw-ups","product_tag-3-phase-ups","product_tag-31-ups","product_tag-3u-ups","product_tag-aps-rtx","product_tag-data-centre-ups","product_tag-double-conversion-ups","product_tag-external-battery-ups","product_tag-long-run-ups","product_tag-network-ups","product_tag-online-ups","product_tag-parallel-ups","product_tag-pf1-0-ups","product_tag-pl31-fl-10-0k-hc","product_tag-power-backup","product_tag-powerline-flex","product_tag-rack-mount-ups","product_tag-rack-tower-ups","product_tag-redundant-ups","product_tag-server-ups","product_tag-single-phase-output-ups","product_tag-three-phase-ups","product_tag-tower-ups","product_tag-ups-ghana","first","instock","taxable","shipping-taxable","purchasable","product-type-composite"],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/axtron.group\/store\/wp-json\/wp\/v2\/product\/236","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/axtron.group\/store\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/axtron.group\/store\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/axtron.group\/store\/wp-json\/wp\/v2\/comments?post=236"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/axtron.group\/store\/wp-json\/wp\/v2\/media\/244"}],"wp:attachment":[{"href":"https:\/\/axtron.group\/store\/wp-json\/wp\/v2\/media?parent=236"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/axtron.group\/store\/wp-json\/wp\/v2\/product_brand?post=236"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/axtron.group\/store\/wp-json\/wp\/v2\/product_cat?post=236"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/axtron.group\/store\/wp-json\/wp\/v2\/product_tag?post=236"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}