Description
The APS-RTx PowerCore Flex PC33 FL 20.0K-E is a high-performance 20kVA / 20kW three-phase online UPS designed to protect critical IT, communications and business infrastructure from power interruptions and poor power quality.
Using online double-conversion technology, the UPS continuously conditions incoming power before supplying the connected load, providing stable voltage and frequency together with zero transfer time from utility to battery operation.
With a 1.0 output power factor, the PC33 FL 20.0K-E delivers its full 20kW of usable active power, making it particularly suitable for modern servers, networking equipment and other high-density electronic loads.
Its three-level inverter topology improves conversion efficiency and reduces switching losses, delivering AC-mode efficiency of up to 95.5% while maintaining excellent output power quality.
The UPS uses a 3-phase input / 3-phase output architecture and supports 380V, 400V and 415V electrical systems commonly used in commercial and industrial facilities.
Despite its 20kW capacity, the system occupies only 3U of rack space and can be configured for rack or tower installation.
For applications requiring increased availability or future capacity expansion, compatible units can be operated in parallel to provide N+X redundancy or additional system capacity.
The PC33 FL 20.0K-E uses an external battery system, allowing battery capacity and backup duration to be engineered according to the requirements of each installation.
Key Features
- 20kVA / 20kW rated capacity
- 1.0 output power factor
- Online double-conversion topology
- 3-phase input / 3-phase output
- 380 / 400 / 415VAC operation
- Three-level inverter topology
- AC efficiency up to 95.5%
- High-efficiency ECO operating mode
- Input power factor ≥0.99
- Low input harmonic distortion
- Zero transfer time from utility to battery
- Pure sine-wave output
- Output voltage regulation ±1%
- Compact 3U design
- Rack/Tower installation
- External battery system
- Programmable battery configuration
- Parallel operation supported
- N+X redundancy
- Capacity expansion capability
- Dual-input capability
- Generator compatible
- Intelligent charging management
- LCD status display
- USB communication
- RS232 communication
- RS485 communication
- Intelligent communication slot
- Dry-contact interface
- Emergency Power Off
- Backfeed protection
- Intelligent fan control
- Overload protection
- Short-circuit protection
- Battery protection
- Over-temperature protection
Typical Applications
Suitable for:
- Data centres
- Server rooms
- Banking and financial systems
- Telecommunications facilities
- Network infrastructure
- Communications equipment
- Critical business IT systems
- CCTV and security control rooms
- Access-control infrastructure
- Industrial control systems
- Automation systems
- Laboratory equipment
- Medical support equipment
- Enterprise IT infrastructure
- Mission-critical commercial facilities
Technical Specifications
| Specification | PC33 FL 20.0K-E |
|---|---|
| UPS Technology | Online Double Conversion |
| Rated Capacity | 20,000VA / 20,000W |
| Output Power Factor | 1.0 |
| Topology | Three-Level Inverter |
| Input Phase | 3 Phase + Neutral + Earth |
| Output Phase | 3 Phase + Neutral + Earth |
| Nominal Input Voltage | 380 / 400 / 415VAC |
| Input Operating Range | 138–485VAC |
| Input Power Factor | ≥0.99 |
| Input THDi | ≤3% with linear load |
| Nominal Output Voltage | 380 / 400 / 415VAC |
| Output Voltage Regulation | ±1% |
| Output Frequency | 50 / 60Hz |
| Output Waveform | Pure Sine Wave |
| Crest Factor | 3:1 |
| Output THDv | ≤2% with linear load |
| AC Efficiency | Up to 95.5% |
| Transfer Time – Utility to Battery | 0ms |
| Parallel Operation | Yes |
| Redundancy | N+X Supported |
| Maximum Parallel Units | Up to 4 units |
| Battery Configuration | External Battery System |
| Internal Batteries | None |
| Battery Type | External VRLA battery system |
| Communications | USB, RS232, RS485, Intelligent Slot |
| Generator Compatible | Yes |
| EPO / REPO | Supported |
| Installation | Rack / Tower |
| Rack Height | 3U |
| Operating Temperature | 0–40°C |
| Humidity | 0–95%, non-condensing |
The OEM HPM3300E-RT platform specifies a 138–485VAC input range, ≥0.99 input PF, ≤3% THDi, ±1% output regulation and parallel redundancy for this series.
External Battery System
The PC33 FL 20.0K-E does not contain internal batteries.
An appropriate external battery bank is therefore required to provide backup power during utility failure.
The external battery architecture allows the system to be configured according to the required runtime, with battery capacity selected based on:
- Connected load
- Required backup duration
- Battery technology
- Installation environment
- Redundancy requirements
Compatible rack-mounted battery packs can be installed alongside the UPS to create a complete integrated backup-power system.

APS-RTx PowerLine Flex PL31-20K-P2-B2-KIT – 2 × 10kVA/10kW Power Modules + 2 × 2.16kWh Battery Boxes, 20kVA/20kW Parallel Online UPS System
APS-RTx PowerLine Flex PL31-20K-P2-B2-KIT – 2 × 10kVA/10kW Power Modules + 2 × 2.16kWh Battery Boxes, 20kVA/20kW Parallel Online UPS System → APS-RTx PowerLine Flex PL31 FL 10.0k HC – 10kVA/10kW 3:1 Online Rack/Tower UPS PM
APS-RTx PowerLine Flex PL31-20K-P2-B2-KIT – 2 × 10kVA/10kW Power Modules + 2 × 2.16kWh Battery Boxes, 20kVA/20kW Parallel Online UPS System → APS-RTx PowerLine Flex PL31-BR20120FL – 20×12V 9Ah Rack Battery Pack for 6kVA & 10kVA UPS BM 